Fault phenomenon |
Cause of issue | Solution |
Ejector Air Leak | Foreign matter or damage inside the Ejector Temperature below 5 ° C There is water vapor in the Ejector |
When the ejector is in normal operation, there is a certain requirement for the flowing air. If the air contains moisture or too many other magazines, the ejector will leak. Color sorting when the ejector is leaking will result in a decrease in the color sorting effect and affect the stability of the air path. Once there is a leak in the ejector, it indicates that the ejector has been damaged by the customer. It is necessary to contact the after-sales service department of the company to send a professional to replace the damaged ejector. |
Ejector no action | Poor contact between the ejector plug and the ejector seat Ejector Coil Broken Ejector PCB Broken |
There are several reasons for the valve no action. The customer can remove the fault step by step according to the following steps. First, check the connection of the ejector circuit. If there is any connector disconnection, please disconnect the whole power supply of the machine, re-connect it and then turn on to check for the possibility of malfunction due to poor contact between the ejector connector and the ejector base. In the case of normal connection, it is necessary to detect the failure of the ejector drive circuit (including the fuse on the circuit board), and strictly observe the safety of the operation when you check it yourself. You can also contact the after-sales service department of the company to send a professional check and repair. |
Ejector Low Air output Ejector Nozzle no air out |
Air pressure is too low | Check if the working pressure of the color sorter is normal Check if the pneumatic line switch is open. |
Material Bouncing on chute |
The chute is scratched High temperature of the material chute dust agglomeration |
Bouncing will cause the color sorting effect to decrease. Generally, the new commissioning machine material bouncing, please check the chute for paint or scratch first. Then check whether the heating device is turned on. If it is not turned on, first turn on the heating device preheating chute for 20-30 minutes. We can also check for dust agglomeration on the chute. If there is any, please refer to the instructions in the front dust cleaning to clean the chute. |
Color sorting quality is getting worse |
Dust on the glass before and after sorting inside the room to block the light Sensitivity, background plate, and flow rate change significantly |
There are many reasons for this, and we need to check them one by one. First of all, we need to check whether the cleaning device is normal, and then check whether the raw material has a large change. If there is a large impurity change, the color selection parameter needs to be re-adjusted. |
No sorting | Sensitivity setting is too low Control system parameters change or malfunction Background board setting is not proper |
First of all, we can check the color sorting plan and the relevant parameters of the whole machine with reference to the color sorter front panel led indicators and the abnormal operation of the ejectors. After excluding the above reasons, there may be some problems with the control circuit board. If it is difficult to discharge by yourself, please feel free to contact the after-sales service department of the company to send a professional. |
Rodless cylinder sliding blocked |
There is resistance in operation |
First check if there is too much ash on the rodless cylinder. If it is, use a rag to clean it with alcohol. Then check the surface for damage, and close the air, push the brush with your hand. If you still can't move it, you need to contact the after-sales engineer for maintenance. |